SCHNEIDER LC1D50AM7
3 marzo, 2018
SCHNEIDER LC1D80M7
3 marzo, 2018
Show all

SCHNEIDER LC1D80F7

SCHNEIDER LC1D80F7 Contactores TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 80 A – 110 V AC 50/60 Hz coil

Categoría:

Especificaciones:

 

gama de producto
TeSys D
gama
TeSys
nombre del producto
TeSys D
tipo de producto o componente
Conector
nombre corto del dispositivo
LC1D
aplicación del contactor
Control del motor
Carga resistiva
categoría de empleo
AC-1
AC-3
AC-4
número de polos
3P
composición de los polos de contacto
3 NA
[Ue] tensión asignada de empleo
<= 690 V AC for power circuit
<= 300 V DC 25…400 Hz for power circuit
[Ie] corriente asignada de empleo
125 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
80 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
potencia del motor en kW
22 kW at 220…230 V AC 50/60 Hz AC-3
37 kW at 380…400 V AC 50/60 Hz AC-3
45 kW at 660…690 V AC 50/60 Hz AC-3
45 kW at 415…440 V AC 50/60 Hz AC-3
55 kW at 500 V AC 50/60 Hz AC-3
45 kW at 1000 V AC 50/60 Hz AC-3
15 kW at 400 V AC 50/60 Hz AC-4
potencia del motor en HP
20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
7.5 hp at 115 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
25 hp at 230/240 V AC 50/60 Hz for 3 phases motors
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
tipo de circuito de control
AC 50/60 Hz
[Uc] tensión del circuito de control
110 V AC 50/60 Hz
composición de los contactos auxiliares
1 NA + 1 NC
[Uimp] Tensión asignada de resistencia a los choques
Conforming to IEC 60947
categoría de sobretensión
III
[Ith] corriente térmica convencional
125 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
Irms poder de conexión nominal
1100 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
poder asignado de corte
1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] Corriente temporal admisible
135 A <= 40 °C 10 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
640 A <= 40 °C 10 s power circuit
990 A <= 40 °C 1 s power circuit
320 A <= 40 °C 1 min power circuit
fusible asociado
160 A gG en <= 690 V coordinación tipo 2 para circuito de alimentación
200 A gG en <= 690 V coordinación tipo 1 para circuito de alimentación
10 A gG para circuito de señalización acorde a IEC 60947-5-1
impedancia media
0.8 mOhm en 50 Hz – Ith 125 A para circuito de alimentación
[Ui] tensión asignada de aislamiento
1000 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for signalling circuit conforming to IEC 60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
durabilidad eléctrica
0.8 Mcycles 125 A AC-1 at Ue <= 440 V
1.5 Mcycles 80 A AC-3 at Ue <= 440 V
potencia disipada por polo
5.1 W AC-3
12.5 W AC-1
cubierta protectora
Con
tipo de montaje
Placa
Carril
normas
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
certificaciones de producto
BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
conexiones – terminales
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Power circuit: connector 1 cable(s) 4…50 mm² – cable stiffness: flexible – without cable end
Power circuit: connector 2 cable(s) 4…25 mm² – cable stiffness: flexible – without cable end
Power circuit: connector 1 cable(s) 4…50 mm² – cable stiffness: flexible – with cable end
Power circuit: connector 2 cable(s) 4…16 mm² – cable stiffness: flexible – with cable end
Power circuit: connector 1 cable(s) 4…50 mm² – cable stiffness: solid – without cable end
Power circuit: connector 2 cable(s) 4…25 mm² – cable stiffness: solid – without cable end
par de apriete
Power circuit: 9 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 9 N.m – on connector hexagonal 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
duración de maniobra
20…35 ms closing
6…20 ms opening
nivel de fiabilidad de seguridad
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
endurancia mecánica
4 Mcycles
rango de operación
3600 cyc/h at <= 60 °C
característica de la bobina
Sin filtro antiparasitario de serie
límites de tensión del circuito de control
0.85…1.1 Uc operational at 55 °C, AC 60 Hz
0.3…0.6 Uc drop-out at 55 °C, AC 50/60 Hz
0.8…1.1 Uc operational at 55 °C, AC 50 Hz
Consumo a la llamada en VA
245 VA at 20 °C (cos ϕ 0.75) 60 Hz
245 VA at 20 °C (cos ϕ 0.75) 50 Hz
consumo de mantenimiento en VA
26 VA at 20 °C (cos ϕ 0.3) 60 Hz
26 VA at 20 °C (cos ϕ 0.3) 50 Hz
disipación de calor
6…10 W at 50/60 Hz
tipo de contactos auxiliares
Tipo unido mecánicamente (1 NA + 1 NC) acorde a IEC 60947-5-1
Tipo contacto espejo (1 NC) acorde a IEC 60947-4-1
frecuencia del circuito de señalización
25…400 Hz
corriente mínima de conmutación
5 mA for signalling circuit
tensión mínima de conmutación
17 V for signalling circuit
tiempo de no superposición
1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
resistencia de aislamiento
> 10 MOhm for signalling circuit
compatibilidad de contacto
M11
código de compatibilidad
LC1D
rango de potencia
15…25 kW 200…240 V 3 phases
30…50 kW 380…440 V 3 phases
30…50 kW 480…500 V 3 phases
55…100 kW 480…500 V 3 phases
tipo de arranque motor
Contactor directo
tension de la bobina del contactor
110 V AC standard
grado de protección IP
IP20 front face conforming to IEC 60529
tratamiento de protección
TH conforming to IEC 60068-2-30
grado de contaminación
3
temperatura ambiente de funcionamiento
-5…60 °C
temperatura ambiente de almacenamiento
-60…80 °C
temperatura ambiente admisible alrededor del dispositivo
-40…70 °C at Uc
altitud máxima de funcionamiento
3000 m without derating in temperature
resistencia al fuego
850 °C conforming to IEC 60695-2-1
resistencia a las llamas
V1 conforming to UL 94
resistencia mecánica
Vibrations contactor open 2 Gn, 5…300 Hz
Shocks contactor open 8 Gn for 11 ms
Vibrations contactor closed 3 Gn, 5…300 Hz
Shocks contactor closed 10 Gn for 11 ms
altura
127 mm
anchura
85 mm
profundidad
130 mm
peso del producto
1.59 kg