HF-P 218/236 TL-D III 220-240V 50/60 Hz
General Information:
Application Code |
III
|
Type Version |
IDC
|
Lamp Type |
TL-D
|
Number of Lamps |
2 piece/unit
|
Number of Products on MCB (16A Type B) (Nom) |
28
|
Automatic Restart |
Yes
|
Operating and Electrical:
Input Voltage |
220 to 240 V
|
Input Frequency |
50 to 60 Hz
|
Operating Frequency (Nom) |
45 kHz
|
Ignition Method |
Programmed Start
|
Crestfactor (Max) |
1.7
|
Power Factor 100% Load (Nom) |
0.99
|
Ignition Time (Max) |
0.9 s
|
Mains Voltage Performance (AC) |
-8%-+6%
|
Mains Voltage Safety (AC) |
-10%-+10%
|
Earth Leakage Current (Nom) |
0.5 mA
|
Inrush Current Width |
0.25 ms
|
Constant Wattage Deviation |
-2%/+2%
|
Ballast Factor (Nom) |
1
|
Power Losses (Nom) |
3.2-4.9 W
|
Inrush Current Peak (Max) |
18 A
|
Wiring:
Connector Type Input Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
Cable Capacity Output Wires Mutual (Nom) |
200 pF
|
Connector Type Output Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
Cable Length Hot Wiring |
0.75 m
|
Wire Striplength |
8.0-9.0 mm
|
Dual Fixture Master/Slave |
Not applicable [ Master/Slave oper. not applicable]
|
Input Terminal Cross Section |
0.50-1.00 mm²
|
Output Terminal Cross Section |
0.50-1.00 mm²
|
Cable Capacity Output Wires to Earth (Nom) |
200 pF
|
System characteristics:
Rated Ballast-Lamp Power |
36/18 W
|
Rated Lamp Power on TL-D |
36/18 W
|
System Power on TL-D |
69.3/38.7 W
|
Lamp Power on TL-D |
64.4/35.5 W
|
Power Loss on TL-D |
4.9/3.2 W
|
Rated Lamp Power on PL-L |
36 W
|
System Power on PL-L |
67.5 W
|
Lamp Power on PL-L |
63.3 W
|
Power Loss on PL-L |
4.2 W
|
Temperature:
T-Ambient (Max) |
60 °C
|
T-Ambient (Min) |
-25 °C
|
T-Storage (Max) |
50 °C
|
T-Storage (Min) |
-40 °C
|
T-Case Lifetime (Nom) |
80 °C
|
T-Case Maximum (Max) |
80 °C
|
T-Ignition (Max) |
60 °C
|
T-Ignition (Min) |
-25 °C
|
Mechanical and Housing:
Housing |
L 280x30x28
|
Emergency Operation:
Nominal Light Output After 60 Seconds |
100% of EBLF
|
Battery Voltage Lamp Ignition |
186-275 V
|
Normal Operating Voltage (DC) |
220-240 V
|
Battery Voltage Lamp Operation |
186-275
|
Battery Voltage Guaranteed Operation |
176-275 V
|
Battery Voltage Guaranteed Ignition |
186-275 V
|
Emergency Ballast Lumen Factor (EBLF) (Nom) |
0.7 %
|
Nominal Light Output After 5 Seconds |
50% of EBLF
|
Approval and Application:
Energy Efficiency Index |
A2 BAT
|
IP Classification |
IP 20 [ Ingress Protection 20]
|
EMI 9 kHz … 30 MHz |
EN55015
|
EMI 30 MHz … 1000 MHz |
EN55022 level B
|
Safety Standard |
IEC 61347-2-3
|
Performance Standard |
IEC 60929
|
Quality Standard |
ISO 9000:2000
|
Environmental Standard |
ISO 14001
|
Harmonic Current Emission Standard |
IEC 61000-3-2
|
EMC Immunity Standard |
IEC 61547
|
Vibration Standard |
IEC68-2-6 F c
|
Bumps Standard |
IEC 68-2-29 Eb
|
Humidity Standard |
EN 61347-2-3 clause 11
|
Approval Marks |
CE marking ENEC certificate VDE-EMV certificate |
Temperature Marking |
Yes
|
Emergency Standard |
IEC 60598-2-22
|
Hum And Noise Level |
< 30 dB(A)
|
Product Data:
Full product code |
872790091166400
|
Order product name |
HF-P 218/236 TL-D III 220-240V 50/60 Hz
|
EAN/UPC – Product |
8711500999665
|
Order code |
913713031666
|
Numerator – Quantity Per Pack |
1
|
Numerator – Packs per outer box |
12
|
Material Nr. (12NC) |
913713031666
|
Net Weight (Piece) |
0.203 kg
|