General Information:
| Application Code | III | 
| Type Version | IDC | 
| Lamp Type | TL-D | 
| Number of Lamps | 2 piece/unit | 
| Number of Products on MCB (16A Type B) (Nom) | 28 | 
| Automatic Restart | Yes | 
Operating and Electrical:
| Input Voltage | 220 to 240 V | 
| Input Frequency | 50 to 60 Hz | 
| Operating Frequency (Nom) | 45 kHz | 
| Ignition Method | Programmed Start | 
| Crestfactor (Max) | 1.7 | 
| Power Factor 100% Load (Nom) | 0.99 | 
| Ignition Time (Max) | 0.9 s | 
| Mains Voltage Performance (AC) | -8%-+6% | 
| Mains Voltage Safety (AC) | -10%-+10% | 
| Earth Leakage Current (Nom) | 0.5 mA | 
| Inrush Current Width | 0.25 ms | 
| Constant Wattage Deviation | -2%/+2% | 
| Ballast Factor (Nom) | 1 | 
| Power Losses (Nom) | 3.2-4.9 W | 
| Inrush Current Peak (Max) | 18 A | 
Wiring:
| Connector Type Input Terminals | WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] | 
| Cable Capacity Output Wires Mutual (Nom) | 200 pF | 
| Connector Type Output Terminals | WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring] | 
| Cable Length Hot Wiring | 0.75 m | 
| Wire Striplength | 8.0-9.0 mm | 
| Dual Fixture Master/Slave | Not applicable  [ Master/Slave oper. not applicable] | 
| Input Terminal Cross Section | 0.50-1.00 mm² | 
| Output Terminal Cross Section | 0.50-1.00 mm² | 
| Cable Capacity Output Wires to Earth (Nom) | 200 pF | 
System characteristics:
| Rated Ballast-Lamp Power | 36/18 W | 
| Rated Lamp Power on TL-D | 36/18 W | 
| System Power on TL-D | 69.3/38.7 W | 
| Lamp Power on TL-D | 64.4/35.5 W | 
| Power Loss on TL-D | 4.9/3.2 W | 
| Rated Lamp Power on PL-L | 36 W | 
| System Power on PL-L | 67.5 W | 
| Lamp Power on PL-L | 63.3 W | 
| Power Loss on PL-L | 4.2 W | 
Temperature:
| T-Ambient (Max) | 60 °C | 
| T-Ambient (Min) | -25 °C | 
| T-Storage (Max) | 50 °C | 
| T-Storage (Min) | -40 °C | 
| T-Case Lifetime (Nom) | 80 °C | 
| T-Case Maximum (Max) | 80 °C | 
| T-Ignition (Max) | 60 °C | 
| T-Ignition (Min) | -25 °C | 
Mechanical and Housing:
| Housing | L 280x30x28 | 
Emergency Operation:
| Nominal Light Output After 60 Seconds | 100% of EBLF | 
| Battery Voltage Lamp Ignition | 186-275 V | 
| Normal Operating Voltage (DC) | 220-240 V | 
| Battery Voltage Lamp Operation | 186-275 | 
| Battery Voltage Guaranteed Operation | 176-275 V | 
| Battery Voltage Guaranteed Ignition | 186-275 V | 
| Emergency Ballast Lumen Factor (EBLF) (Nom) | 0.7 % | 
| Nominal Light Output After 5 Seconds | 50% of EBLF | 
Approval and Application:
| Energy Efficiency Index | A2 BAT | 
| IP Classification | IP 20  [ Ingress Protection 20] | 
| EMI 9 kHz … 30 MHz | EN55015 | 
| EMI 30 MHz … 1000 MHz | EN55022 level B | 
| Safety Standard | IEC 61347-2-3 | 
| Performance Standard | IEC 60929 | 
| Quality Standard | ISO 9000:2000 | 
| Environmental Standard | ISO 14001 | 
| Harmonic Current Emission Standard | IEC 61000-3-2 | 
| EMC Immunity Standard | IEC 61547 | 
| Vibration Standard | IEC68-2-6 F c | 
| Bumps Standard | IEC 68-2-29 Eb | 
| Humidity Standard | EN 61347-2-3 clause 11 | 
| Approval Marks | CE marking ENEC certificate VDE-EMV certificate | 
| Temperature Marking | Yes | 
| Emergency Standard | IEC 60598-2-22 | 
| Hum And Noise Level | < 30 dB(A) | 
Product Data:
| Full product code | 872790091166400 | 
| Order product name | HF-P 218/236 TL-D III 220-240V 50/60 Hz | 
| EAN/UPC – Product | 8711500999665 | 
| Order code | 913713031666 | 
| Numerator – Quantity Per Pack | 1 | 
| Numerator – Packs per outer box | 12 | 
| Material Nr. (12NC) | 913713031666 | 
| Net Weight (Piece) | 0.203 kg | 